TK6070-FBS Weintek HMI to Fatek PLC Communication Cable

Weintek HMI to Fatek PLC Communication Cable Price in Bangladesh/ TK6070-FBS seller in Bangladesh

Brand: AMSAMOTION

Model: TK-FBS

Origin: China

Ask Price  Call/WhatsApp: +8801713-722455

Description

The TK6070-FBS Weintek HMI to Fatek PLC Communication Cable is used to establish communication between a Weintek HMI (specifically the TK6070 series or similar models) and a Fatek PLC. This cable allows for data transfer, monitoring, and control between the HMI and the Fatek PLC, enabling real-time communication for automation processes. If you need TK6070-FBS Weintek HMI to Fatek PLC Communication Cable, you can contact BAT Power Solution Via WhatsAPP/Call: +8801713722455

Key Features TK6070-FBS Weintek HMI to Fatek PLC Communication Cable 

  • HMI to Fatek PLC Communication: Specifically designed for connecting Weintek HMIs (such as the TK6070 series) to Fatek PLCs.
  • Supports RS232 or RS485 Communication Protocols: Depending on the Fatek PLC model and communication port, the cable can handle RS232 or RS485 protocols.
  • Easy Setup: Simplifies communication between the HMI and PLC, reducing the complexity of wiring for automation projects.

Others Cable

Cable Specifications

  1. HMI End:
    • The connector at the Weintek HMI end typically fits into the communication port on the HMI, such as RS232 (DB9 or RJ45) or RS485, depending on the specific HMI model.
  2. Fatek PLC End:
    • The other end of the cable connects to the communication port of the Fatek PLC. This is generally either an RS232 port (DB9 connector) or an RS485 port, depending on the Fatek PLC model.
  3. Supported Communication Protocols:
    • RS232 or RS485 communication, ensuring compatibility with the Fatek PLC’s communication standards.

Supported Weintek HMI Models

  • Weintek TK6070 Series HMIs:
    • TK6070iH, TK6070iQ, TK6071iP, and similar models in the Weintek HMI lineup that support RS232 or RS485 communication.

Supported Fatek PLC Models

  • Fatek FBs Series PLCs:
    • Models like FBs-10MC, FBs-14MC, FBs-20MC, and other FBs series PLCs.

Connection Setup Weintek HMI to Fatek PLC Communication Cable

  1. Connect the Weintek HMI End of the TK6070-FBS cable to the communication port of the TK6070 series HMI (or compatible model).
  2. Connect the Fatek PLC End to the communication port on the Fatek PLC.
  3. Launch EasyBuilder Pro (Weintek’s HMI programming software) or the appropriate Fatek software.
  4. In EasyBuilder Pro, configure the communication settings (such as RS232 or RS485, baud rate, parity, etc.) to match the settings on the Fatek PLC.
  5. Test the connection to verify proper communication between the HMI and the PLC.

Software Used TK6070-FBS Weintek HMI to Fatek PLC Communication Cable

  • EasyBuilder Pro: The software used to program and configure Weintek HMIs. It allows users to set up communication between the HMI and various PLCs, including Fatek.
  • Fatek Programming Software: Software such as WinProLadder can be used to program the Fatek PLC.

Troubleshooting Tips

  • Communication Settings: Ensure that the baud rate, data bits, stop bits, and parity settings match between the HMI and PLC.
  • Cable Connection: Check that the cable is securely connected to both the HMI and PLC and that the correct ports are used.
  • Driver Issues: If using a USB-to-RS232 or RS485 adapter, ensure that the drivers are properly installed on your computer.

Important Notes

  • Always verify the communication protocol (RS232 or RS485) that both the Weintek HMI and Fatek PLC support.
  • Ensure the communication settings in both EasyBuilder Pro and Fatek’s programming environment are properly configured for successful data exchange

Reviews