
Simatic S7 1200 CPU 1214C AC DC Rly
Siemens 6es7 214 1bg40 0xb0 Price in Bangladesh
Model: 6es7 214 1bg40 0xb0
Origin: China
Ask Price Call/WhatsApp: +8801713722455
Description
The Simatic S7 1200 CPU 1214C AC DC Rly is the Compact Programmable Logic Controller (PLC) of Siemens AG. The CPU 1214C AC/DC/Relay part number is 6ES7214-1BG40-0XB0. The PLC Has integrated Digital input & digital Output also has Analog Input. This 1214C AC/DC/Relay has 14 digital input which are voltage 24V DC, and 10 digital output Relay, 2 Analog input DC Voltage (0-10V). This Programmable Logic Controller (PLC) 6ES7214-1BG40-0XB0 PLC has Power Supply is AC Voltage (85-264V).
Specification of Simatic S7 1200 CPU 1214C AC DC Rly
Part number | 6ES7214-1BG40-0XB0 |
General information | |
Product type designation | CPU 1214C AC/DC/relay |
Firmware version | V4.6 |
Engineering with | |
● Programming package | STEP 7 V18 or higher |
Supply voltage | |
Rated value (AC) | |
● 120 V AC | Yes |
● 230 V AC | Yes |
permissible range, lower limit (AC) | 85 V |
permissible range, upper limit (AC) | 264 V |
Line frequency | |
● permissible range, lower limit | 47 Hz |
● permissible range, upper limit | 63 Hz |
Input current | |
Current consumption (rated value) | 100 mA at 120 V AC; 50 mA at 240 V AC |
Current consumption, max. | 300 mA at 120 V AC; 150 mA at 240 V AC |
Inrush current, max. | 20 A; at 264 V |
I²t | 0.8 A²·s |
Output current | |
for backplane bus (5 V DC), max. | 1 600 mA; Max. 5 V DC for SM and CM |
Encoder supply | |
24 V encoder supply | |
● 24 V | 20.4 to 28.8V |
Power loss | |
Power loss, typ. | 14 W |
Memory | |
Work memory | |
● integrated | 150 kbyte |
Load memory | |
● integrated | 4 Mbyte |
● Plug-in (SIMATIC Memory Card), max. | with SIMATIC memory card |
Backup | |
● present | Yes |
● maintenance-free | |
● without battery | |
CPU processing times | |
for bit operations, typ. | 0.08 µs; / instruction |
for word operations, typ. | 1.7 µs; / instruction |
for floating point arithmetic, typ. | 2.3 µs; / instruction |
CPU-blocks | |
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
OB | |
● Number, max. | Limited only by RAM for code |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
Flag | |
● Size, max. | 8 kbyte; Size of bit memory address area |
Local data | |
● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
Address area | |
Process image | |
● Inputs, adjustable | 1 kbyte |
● Outputs, adjustable | 1 kbyte |
Hardware configuration | |
Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
Time of day | |
Clock | |
● Hardware clock (real-time) | Yes |
● Backup time | 480 h; Typical |
● Deviation per day, max. | ±60 s/month at 25 °C |
Digital inputs | |
Number of digital inputs | 14; Integrated |
● of which inputs usable for technological functions | 6; HSC (High Speed Counting) Yes |
Source/sink input | |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 40 °C, max. | 14 |
Input voltage | |
● Rated value (DC) | 24 V |
● for signal “0” | 5 V DC at 1 mA |
● for signal “1” | 15 V DC at 2.5 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in |
groups of four | |
— at “0” to “1”, min. | 0.2 ms |
— at “0” to “1”, max. | 12.8 ms |
for interrupt inputs | |
— parameterizable | Yes |
for technological functions | |
— parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
Cable length | |
● shielded, max. | 500 m; 50 m for technological functions |
● unshielded, max. | 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 10; Relays |
Switching capacity of the outputs | |
● with resistive load, max. | 2:00 AM |
● on lamp load, max. | 30 W with DC, 200 W with AC |
Output delay with resistive load | |
● “0” to “1”, max. | 10 ms; max. |
● “1” to “0”, max. | 10 ms; max. |
Relay outputs | |
● Number of relay outputs | 10 |
● Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 |
Cable length | |
● shielded, max. | 500 m |
● unshielded, max. | 150 m |
Analog inputs | |
Number of analog inputs | 2 |
Input ranges | |
● Voltage | Yes |
Input ranges (rated values), voltages | |
● 0 to +10 V | Yes |
— Input resistance (0 to 10 V) | ≥100k ohms |
Cable length | |
● shielded, max. | 100 m; twisted and shielded |
Analog outputs | |
Number of analog outputs | 0 |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 10 bit |
● Integration time, parameterizable | Yes |
● Conversion time (per channel) | 625 µs |
Encoder | |
Connectable encoders | |
● 2-wire sensor | Yes |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types | |
● RJ 45 (Ethernet) | Yes |
● Number of ports | 1 |
● integrated switch | No |
Protocols | |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | Yes |
● SIMATIC communication | Yes |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | No |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
— Isochronous mode | No |
— IRT | No |
— PROFIenergy | No |
— Prioritized startup | Yes |
— Number of IO devices with prioritized startup, max. | 16 |
— Number of connectable IO Devices, max. | 16 |
— Number of connectable IO Devices for RT, max. | 16 |
— of which in line, max. | 16 |
— Activation/deactivation of IO Devices | Yes |
— Number of IO Devices that can be simultaneously | 8 |
activated/deactivated, max. | |
— Updating time | The minimum value of the update time also depends on the communication |
component set for PROFINET IO, on the number of IO devices and the quantity | |
of configured user data. | |
PROFINET IO Device | |
Services | |
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
— Isochronous mode | No |
— IRT | No |
— PROFIenergy | Yes |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 2 |
Protocols | |
Supports protocol for PROFINET IO | Yes |
PROFIsafe | No |
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
OPC UA | Yes; OPC UA Server |
AS-Interface | Yes; CM 1243-2 required |
Protocols (Ethernet) | |
● TCP/IP | Yes |
● DHCP | No |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
Redundancy mode | |
Media redundancy | |
— MRP | No |
— MRPD | No |
SIMATIC communication | |
● S7 routing | Yes |
Open IE communication | |
● TCP/IP | Yes |
— Data length, max. | 8 kbyte |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 8 kbyte |
● UDP | Yes |
— Data length, max. | 1 472 byte |
Web server | |
● supported | Yes |
● User-defined websites | Yes |
OPC UA | |
● Runtime license required | Yes; “Basic” license required |
● OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required |
— Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, |
Basic256Sha256 | |
— User authentication | “anonymous” or by user name & password |
— Number of sessions, max. | 10 |
— Number of subscriptions per session, max. | 5 |
— Sampling interval, min. | 100 ms |
— Publishing interval, min. | 200 ms |
— Number of server methods, max. | 20 |
— Number of monitored items, recommended max. | 1 000 |
— Number of server interfaces, max. | 2 |
— Number of nodes for user-defined server interfaces, | 2 000 |
max. | |
Further protocols | |
● MODBUS | Yes |
communication functions / header | |
S7 communication | |
● supported | Yes |
● as server | Yes |
● as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Number of connections | |
● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved |
/ 10 max; Total Connections: 34 reserved / 64 max | |
Test commissioning functions | |
Status/control | |
● Status/control variable | Yes |
Dimensions | |
Width | 110 mm |
Height | 100 mm |
Depth | 75 mm |
Weights | |
Weight, approx. | 455 g |
Programming Software & Programming Cable Simatic S7 1200 CPU 1214C AC DC Rly
TIA Portal is the programming software of Siemens All Series Programmable Logic Controller (PLC), This is not only PLC Software, also included HMI DRIVE and Controller.
Ethernet USB-ETH is the programming cable of S71200 PLC, HMI, Servo & VFD. Also Ethernet cable is the programming cable of All Ethernet series CPU, HMI, VFD and Servo Drives.
Conclusion
If you need to 6ES7214-1BG40-0XB0 Simatic S7 1200 CPU 1214C AC DC Rly Price in Bangladesh Programmable Logic Controller (PLC), or need to troubleshooting CPU 1214C AC/DC/Relay in Bangladesh, then you can contact “BAT Power Solution” via Call/WhatsApp: +8801713722455. We have stock Available 6ES7214-1BG40-0XB0 in our company “BAT Power Solution” in Bangladesh.
Related products
-
Sale!
Delta PLC DVP32ES200R
21,000.00৳Original price was: 21,000.00৳ .20,500.00৳ Current price is: 20,500.00৳ . Add to cart -
Sale!
Delta DVP14SS211R PLC DVP Series
12,000.00৳Original price was: 12,000.00৳ .9,500.00৳ Current price is: 9,500.00৳ . Add to cart -
Sale!
FX1N-24MR-001 Mitsubishi FX1N PLC Series
18,000.00৳Original price was: 18,000.00৳ .16,500.00৳ Current price is: 16,500.00৳ . Add to cart -
6ED1052 2MD00 0BA8 Siemens Logo Controller
18,000.00৳ Add to cart
Reviews
There are no reviews yet.