Description
The Mitsubishi MELSEC FX2N 32MR 001 is a digital I/O module designed for use with Mitsubishi FX series PLCs. It has 16 digital input & 16 digital output. This module FX2N 32MR 001 provides a versatile solution for expanding the digital input and output capabilities of the PLC system. Here’s a detailed description of its features, specifications, and typical applications:
Key Features Mitsubishi MELSEC FX2N 32MR 001
- Type: Digital Input/Output Module
- I/O Points:
- Digital Inputs: 16 points
- Digital Outputs: 16 points
- Voltage Rating:
- Inputs: DC 24V
- Outputs: DC 24V
Specifications Mitsubishi MELSEC FX2N 32MR 001
- Digital Inputs:
- Channels: 16 points
- Input Voltage: DC 24V
- Input Current: Approximately 3mA per point
- Input Type: NPN transistor input
- Input Impedance: Approximately 2.5kΩ
- Digital Outputs:
- Channels: 16 points
- Output Voltage: DC 24V
- Output Current: 0.1A per point, maximum 0.5A per module
- Output Type: NPN transistor output with short-circuit protection
Mitsubishi PLC Module | FX2N and the FX2NC PLC’s Specification | Remarks |
Operation control method | Cyclic operation by stored program | |
I/O control method | Batch processing method (when END instruction is executed) | I/O refresh instruction is available |
Operation processing time | Basic instructions: 0.08 msApplied instructions: 1.52 to several 100 ms | |
Programming language | Relay symbolic language + step ladder | Step ladder can be used to produce an SFC style program |
Program capacity | 8000 steps built in | Expandable to 16000 steps using additional memory cassette |
Number of instructions | Basic sequence instructions: 20 Step ladder instructions: 2 Applied instructions: 125 | A Maximum 125 applied instructions are available |
I/O configuration | Max hardware I/O configuration points 255, dependent on user selection (Max. software addressable Inputs 255, Outputs 255) | |
Auxiliary relay(M coils) | 3072 points | M0 to M3071 |
Auxiliary relay(M coils) | ||
General | ||
Auxiliary relay(M coils) | 2572 points (subset) | M500 to M3071 |
Latched | ||
Auxiliary relay(M coils) | 256 points | From the range M8000 to M8255 |
Special | ||
State relays (S coils) | 1000 points | S0 to S999 |
General | ||
State relays (S coils) Latched | 500 points (subset) | S500 to S999 |
State relays (S coils) Initial | 10 points (subset) | S0 to S9 |
State relays (S coils) Annunciator | 100 points | S900 to S999 |
Timers (T) 100 msec | Range: 0 to 3,276.7 sec200 points | T0 to T199 |
Timers (T) 10 msec | Range: 0 to 327.67 sec46 points | T200 to T245 |
Timers (T) 1 msec retentive | Range: 0 to 32.767 sec4 points | T246 to T249 |
Timers (T) 100 msec retentive | Range: 0 to 3,276.7 sec6 points | T250 to T255 |
Counters (C) General 16 bit | Range: 1 to 32,767 counts200 points | C0 to C199Type: 16 bit up counter |
Counters (C) | 100 points (subset) | C100 to C199Type: 16 bit up counter |
General 16 bit | ||
Latched 16 bit | ||
Counters (C) General 16 bit | Range: -2,147,483,648 to 2,147,483,64735 points | C200 to C234Type: 32 bit up/down counter |
General 32 bit | ||
Counters (C) General 16 bit | 15 points (subset) | C219 to C234Type: 16 bit up/down counter |
Latched 32 bit |
Applications:
- Factory Automation: Ideal for controlling machines, conveyors, and other automated systems that require digital I/O signals.
- Process Control: Used in applications requiring the control of various digital devices and actuators.
- Building Automation: Suitable for controlling lighting, HVAC systems, and other building management tasks.
Benefits:
- Compact Design: Space-saving design suitable for installation in control panels with limited space.
- Reliability: Robust construction ensures reliable performance in industrial environments.
- Ease of Installation: Designed for quick and easy installation on a DIN rail, with clear labeling for straightforward wiring.
Installation and Configuration:
- Mounting:
- Secure the FX2N-32MR-001 module on a DIN rail inside a control panel.
- Wiring:
- Connect the digital inputs and outputs to the appropriate terminals, following the wiring diagrams provided in the user manual.
- Software Setup:
- Use Mitsubishi’s GX Works2 or GX Works3 software to configure the module.
- Define the digital input and output points.
- Set the input and output parameters, such as input logic type and output control settings.
- Integrate the module into your PLC program and define the control logic.
- Use Mitsubishi’s GX Works2 or GX Works3 software to configure the module.
- Testing:
- Download the configuration to the PLC.
- Use the PLC’s diagnostic tools to monitor and verify the operation of the digital inputs and outputs.
- Conduct thorough testing to ensure all digital signals are correctly processed and controlled.
The FX2N-32MR-001 is a reliable and efficient digital I/O module for Mitsubishi FX series PLCs. It provides 16 digital input and 16 digital output points, making it suitable for a wide range of industrial automation applications. Proper installation and configuration using Mitsubishi’s software tools will ensure that the module operates effectively in your control systems.
Related products
-
Sale!
Delta PLC DVP14SS211T Delta DVP Series
12,500.00৳Original price was: 12,500.00৳ .10,500.00৳ Current price is: 10,500.00৳ . Add to cart -
Logo 6ED1052 1MD00 0BA8 Siemens PLC
18,000.00৳ Add to cart -
6ED10521MD000BA6 logo plc Siemens
Read more -
Sale!
Delta PLC DVP32ES200R
21,000.00৳Original price was: 21,000.00৳ .20,500.00৳ Current price is: 20,500.00৳ . Add to cart
Reviews
There are no reviews yet.