6ES7331 1KF02 0AB0 Price

Ask Price  WhatsApp: +8801713-722455

Description

The 6ES7331 1KF02 0AB0 Price is Acceptable and It is an analog input module from Siemens, specifically designed for the SIMATIC S7-300 PLC series. This module is used to process analog signals from sensors and transducers in various industrial automation applications. If need to 6es7331 1kf02 0ab0 price, then you can contact “BAT Power Solution” Via WhatsApp: +8801713722455. See the manual Sie 6es7331 1kf02 0ab0, The properties of the module given below

+8 inputs in 8 channel groups
+Programmable resolution for each group (12 bits + sign)
+Measurement types are programmable for each channel group:
– Voltage
– current
– Resistance
– temperature
+Any measurement range per channel
+Motor protection / temperature monitoring with PTC according to IEC 60034-11-2 type A
+Temperature recorded by KTY83/110, KTY84/130 silicon temperature sensor

Key Features of Analog Inputs Module Siemens 6ES7331 1KF02 0AB0

  • The module 6ES7331 1KF02 0AB0 Price provides 8 analog inputs, which can be configured for different types of signals, including voltage and current. This flexibility allows it to interface with a wide range of analog devices.
  1. Signal Range:
    • The module supports different ranges for voltage (±10V, 0-10V, etc.) and current (0-20mA, 4-20mA), making it adaptable to various sensors and transducers used in industrial automation.
  2. Resolution:
    • The module typically offers a resolution of 12 bits, providing a good level of precision for measuring analog signals.
  3. Diagnostic Features:
    • Integrated diagnostic functions help in detecting faults such as wire breaks or sensor malfunctions, which are crucial for maintaining the reliability of the automation system.
  4. Compatibility:
    • It is designed to be used with the SIMATIC S7-300 PLC system, ensuring seamless integration with other modules and components in the S7-300 series.
  5. Connection:
    • The module uses a front connector for wiring the analog inputs, and it’s installed directly on the S7-300 rail alongside other modules.

Specification & 6es7331 1kf02 0ab0 price

Terminal description see the details 6ES7331 1KF02 Analog Input Module & 6ES7331 1KF02 0AB0 Price

Input current  
from backplane bus 5 V DC, max. 90 mA
Power loss  
Power loss, typ. 0.4 W
Analog inputs  
Number of analog inputs 8
●   For resistance measurement 8
30 V; 12 V continuous, 30 V for max. 1 s
permissible input voltage for voltage input (destruction limit), max.
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
●   Voltage Yes
●   Current Yes
●   Thermocouple No
●   Resistance thermometer Yes
●   Resistance Yes
Input ranges (rated values), voltages
●   0 to +10 V Yes
— Input resistance (0 to 10 V) 100 kΩ
●   1 V to 5 V Yes
— Input resistance (1 V to 5 V) 100 kΩ
●   1 V to 10 V No
●   -1 V to +1 V Yes
— Input resistance (-1 V to +1 V) 100 kΩ
●   -10 V to +10 V Yes
— Input resistance (-10 V to +10 V) 100 kΩ
●   -2.5 V to +2.5 V No
●   -250 mV to +250 mV No
●   -5 V to +5 V Yes
— Input resistance (-5 V to +5 V) 100 kΩ
●   -50 mV to +50 mV Yes
— Input resistance (-50 mV to +50 mV) 100 kΩ
●   -500 mV to +500 mV Yes
— Input resistance (-500 mV to +500 mV) 100 kΩ
●   -80 mV to +80 mV No
Input ranges (rated values), currents
●   0 to 20 mA Yes
— Input resistance (0 to 20 mA) 100 Ω
●   -10 mA to +10 mA No
●   -20 mA to +20 mA Yes
— Input resistance (-20 mA to +20 mA) 100 Ω
●   -3.2 mA to +3.2 mA No
●   4 mA to 20 mA Yes
— Input resistance (4 mA to 20 mA) 100 kΩ
Input ranges (rated values), thermocouples
●   Type B No
●   Type C
●   Type E
●   Type J
●   Type K
●   Type L
●   Type N
●   Type R
●   Type S
●   Type T
●   Type U
●   Type TXK/TXK(L) to GOST
Input ranges (rated values), resistance thermometer
●   Cu 10 No
●   Ni 100 Yes; Standard/climate
— Input resistance (Ni 100) 100 MΩ
●   Ni 1000 Yes
— Input resistance (Ni 1000) 100 MΩ
●   LG-Ni 1000 Yes; Standard/climate
— Input resistance (LG-Ni 1000) 100 MΩ
●   Ni 120 No
●   Ni 200 No
●   Ni 500 No
●   Pt 100 Yes; Standard/climate
— Input resistance (Pt 100) 100 MΩ
●   Pt 1000 No
●   Pt 200 No
●   Pt 500 No
Input ranges (rated values), resistors
●   0 to 150 ohms No
●   0 to 300 ohms No
●   0 to 600 ohms Yes
— Input resistance (0 to 600 ohms) 100 MΩ
●   0 to 6000 ohms Yes
— Input resistance (0 to 6000 ohms) 100 MΩ
Thermocouple (TC)
Temperature compensation
— parameterizable No
— internal temperature compensation
— external temperature compensation with compensations socket
Characteristic linearization
●   parameterizable Yes No
— for thermocouples yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.
— for resistance thermometer
Cable length
●   shielded, max. 200 m; max. 50 m at 50 mV
Analog value generation for the inputs
Integration and conversion time/resolution per channel
●   Resolution with overrange (bit including sign), max. 13 bit
●   Integration time, parameterizable Yes; 60 / 50 ms
●   Basic conversion time (ms) 66 / 55 ms
●   Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
Encoder
Connection of signal encoders
●   for voltage measurement Yes
●   for current measurement as 2-wire transducer Yes; with external supply
●   for current measurement as 4-wire transducer Yes
●   for resistance measurement with two-wire connection Yes
●   for resistance measurement with three-wire connection  Yes
●   for resistance measurement with four-wire connection  Yes
Errors/accuracies
Operational error limit in overall temperature range
●   Voltage, relative to input range, (+/-) 0.6 %; ±0.6 % (±5 V, 10 V, 1 to 5 V, 0 to 10 V); ±0.5 % (±50 mV, 500 mV, 1 V)
●   Current, relative to input range, (+/-) 0.5 %; ±20 mA, 0 to 20 mA, 4 to 20 mA
●   Resistance, relative to input range, (+/-) 0.5 %; 0 to 6 kohms, 0 to 600 kohms
●   Resistance thermometer, relative to input range, (+/-) 1 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG- Ni1000, climatic); 1.2 Kelvin (Pt100, Ni100, standard)
Basic error limit (operational limit at 25 °C)
●   Voltage, relative to input range, (+/-) 0.4 %; 0.4% (±5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (±50 mV, 500 mV, 1 V)
●   Current, relative to input range, (+/-) 0.3 %; ±20 mA, 0 to 20 mA, 4 to 20 mA
●   Resistance, relative to input range, (+/-) 0.3 %; 0 to 6 kohms, 0 to 600 kohms
●   Resistance thermometer, relative to input range, (+/-) 1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic)
Interrupts/diagnostics/status information
Diagnostics function No
Alarms
●   Diagnostic alarm No
●   Limit value alarm
Diagnoses
●   Diagnostic information readable No
Diagnostics indication LED
●   Group error SF (red) No
Potential separation
Potential separation analog inputs
●   between the channels No
●   between the channels and backplane bus yes
Isolation
Isolation tested with 500 V DC
connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 117 mm
Weights
Weight, approx. 250 g

 

Technical specification of Siemens 6ES7 331-1KF02-0AB0

 

 

Technical specifications
Dimensions and weight
Dimensions W x H x D (mm) 40 x 125 x 117
Weight ca. 250 g
Module-specific data
Supports isochronous mode no
Number of inputs 8
with resistive transducers 8
Cable length max. 200 m
shielded max. 50 m at 50 mV
Voltages, currents, electrical potentials
Constant current for resistive transducers 0.83 mA (pulsed)
Resistance thermometer and resistance measurements 0 Ω to 600 Ω 0.25 mA (pulsed)
Resistance measurement 0 to 6 kΩ, PTC,
silicon temperature sensors
Electrical isolation yes
between channels and the backplane bus no
between channels
Maximum potential difference 2.0 V DC
between inputs (CMV)
Isolation test voltage 500 V DC
Current consumption max. 90 mA
from the backplane bus
Power loss of the module typ. 0.4 W
Generation of analog values
Measuring principle Integrating
Integration/conversion time/resolution (per channel)
programmable yes
Interference frequency suppression at interference frequency f1 in Hz 50 60
Integration time in ms 60 50
Basic conversion time, including the integration time in ms 66 55
Additional conversion time for resistance measurements in ms 66 55
Resolution in bits (including overshoot range) 13 bits 13 bits
Interference frequency suppression, error limits
Interference frequency suppression at f = n (f1 ± 1 %), (f1 = interference frequency) n=1.2
Common mode interference (VCM < 2 V) > 86 dB
Series­mode interference (peak value < rated input range) > 40 dB
Crosstalk between inputs > 50 dB
Operational limit (across entire temperature range, relative to the measurement range end value in the selected input range)
Voltage input ± 5 V ± 0.6 %
± 10 V
1 V to 5 V
0 V to 10 V
± 50 mV
± 500 mV
±1 V ± 0.5 %
Current input ± 20 mA ± 0.5 %
0 mA to 20 mA
4 mA to 20 mA
Resistor/PTC 0 kΩ to 6 kΩ ± 0.5 %
0 Ω to 600 Ω ± 0.5 %
PTC ± 0.5 %
Resistance thermometer/silicon temperature sensors Pt 100 ± 1.2 K
Ni 100
Standard
Pt 100 ± 1 K
Ni 100
Klima
Ni 1000, ± 1 K
LG-Ni 1000
Standard
Ni 1000 ± 1 K
LG-Ni 1000
Klima
KTY83/110 ± 3.5 K
KTY84/130 ± 4.5 K
Basic error limit (operational limit at 25 °C, relative to the measurement range end value in the selected input range)
Voltage input ± 5 V ± 0.4 %
± 10 V
1 V to 5 V
0 V to 10 V
± 50 mV
± 500 mV
± 1 V ± 0.3 %
Current input ± 20 mA ± 0.3 %
0 to 20 mA
4 mA to 20 mA
Resistor/PTC 0 kΩ to 6 kΩ ± 0.3 %
0 Ω to 600 Ω ± 0.3 %
PTC ± 0.3 %
Resistance thermometer/silicon temperature sensors Pt 100 ± 1 K
Ni 100
Standard
Pt 100 ± 0.8 K
Ni 100
Klima
Ni 1000 ± 0.8 K
LG-Ni 1000
Standard
Ni 1000 ± 0.8 K
LG-Ni
1000 Klima
KTY83/110 ± 2 K
KTY84/130 ± 2.7 K
Temperature error (relative to input range) ± 0.006 %/K /  0.006 K/K
Linearity error (relative to input range) ±  0.1 % /  0.1 K
Repeat accuracy (in transient state at 25 °C, relative to input range) ± 0.1 % / ± 0.1 K
Status, interrupts, diagnostics
Interrupts none
Diagnostic functions none
Encoder selection data
Input ranges (rated values) / input impedance
Voltage ± 50 mV 100 kΩ
± 500 mV
± 1 V
± 5 V
± 10 V
1 V to 5 V
0 V to 10 V
Current ± 20 mA 100 Ω
0 mA to 20 mA
4 mA to 20 mA
Resistor/PTC 0 kΩ to 6 kΩ 100 MΩ
0 Ω to 600 Ω
PTC
Resistance thermometer/silicon temperature sensors Pt 100 100 MΩ
Ni 100
Ni 1000
LG-Ni
1000
Standard / Klima
KTY83/110
KTY84/130
Maximum voltage at voltage input U+ (destruction limit) max. 30 V, continuous
Maximum voltage at voltage inputs M+, M-, S- (destruction limit) max. 12 V continuous; 30 V for a duration of max. 1 s
Maximum current at current input I+ (destruction limit) 40 mA
Wiring of the signal transmitters using a 40­pin front connector
for voltage measurement supported
for current measurement supported, with external supply
– as 2-wire transducer supported
– as 4-wire transducer
for resistance measurement supported
with 2-wire connection supported
with 3-wire connection supported
with 4-wire connection
Characteristics linearization programmable
for resistance thermometers Pt 100 Standard / Klima
Ni 100 Standard / Klima
Ni 1000 Standard / Klima
LG-Ni 1000 Standard / Klima
Technical unit of temperature measurement Degrees Centigrade, degrees Fahrenheit, Kelvin

 

The 6ES7331 1KF02 0AB0 Price/Siemens 6ES7 331-1KF02-0AB0 is a reliable and versatile analog input module for the SIMATIC S7-300 PLC series. Its ability to process a variety of analog signals with high resolution makes it an essential component in many industrial automation systems.