6ES7 288 1SR60 0AA0 SR60 CPU
Ask Price WhatsApp: +8801713-722455
Category: PLC
Tags: 6ES7 288 1SR60 0AA0, 6es7288 1sr60 0aa0, 6ES7288 1SR60 0AA1, S7200 SMART PLC, SR60 CPU
Description
6ES7 288 1SR60 0AA0 SR60 CPU & 6ES7288 1SR60 0AA1 is the programmable Logic Controller of SIMATIC S7-200 SMART series, this part number CPU SR60, CPU is the AC/DC/relay, has onboard I/O: 36 points Digital Input (DI) 24 V DC & 24 Points Digital Outputs (DO) relay 2 A; power supply: AC 85-264 V AC at 47-63 Hz, program/data memory 50 KB.
Specification of 6ES7 288 1SR60 0AA0 SR60 CPU
Part number | 6ES7288-1SR60-0AA0 |
General information | |
Product type designation | CPU SR60 AC/DC/Relay |
Engineering with | |
● Programming package | STEP 7 Micro/WIN SMART |
Installation type/mounting | |
Rail mounting | Yes; Standard – DIN rail |
Supply voltage | |
Rated value (AC) | |
● 120 V AC | Yes |
● 230 V AC | Yes |
permissible range, lower limit (AC) | 85 V |
permissible range, upper limit (AC) | 264 V |
Line frequency | |
● permissible range, lower limit | 47 Hz |
● permissible range, upper limit | 63 Hz |
Input current | |
Current consumption (rated value) | 220 mA; at 240 V AC |
Current consumption, max. | 370 mA; At 120 V AC |
Inrush current, max. | 16.3 A; at 264 V |
Output current | |
Current output, max. | 300 mA; 24 V DC Sensor Power |
for backplane bus (5 V DC), max. | 1.4 A; max. 5 V DC for EM bus |
Power loss | |
Power loss, max. | 25 W |
Memory | |
Type of memory | DDR |
Flash | Yes |
RAM | Yes |
Memory available for user data | 20 kbyte |
Memory size | 30 kbyte; Program memory |
Micro Memory Card | Yes; microSDHC Card (optional) |
Backup | |
● present | Yes; Maintenance free, RTC requires 7 days. |
CPU processing times | |
for bit operations, typ. | 150 ns; / instruction |
for word operations, typ. | 1.2 µs; / instruction |
for floating point arithmetic, typ. | 3.6 µs; / instruction |
Address area | |
I/O address area | |
● Inputs | 144 byte; 256 bit of digital inputs & 56 words of analog inputs |
● Outputs | 144 byte; 256 bit of digital outputs & 56 words of analog outputs |
Time of day | |
Clock | |
● Type | Hardware clock, no battery backup Yes |
● Hardware clock (real-time) | 7 d |
● Backup time | 120 s; within 120s/month at 25 °C |
● Deviation per day, max. | |
Digital inputs | |
Number of digital inputs | 36; Integrated |
● of which inputs usable for technological functions | 4; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 40 °C, max. | 36 |
Input voltage | |
● Type of input voltage | DC |
● Rated value (DC) | 24 V |
● for signal “0” | 5 V DC at 1 mA |
● for signal “1” | 15 V DC at 2.5 mA |
Input current | |
● for signal “0”, max. (permissible quiescent current) | 1 mA |
● for signal “1”, typ. | 4 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
— at “0” to “1”, min. | 0.2 ms |
— at “0” to “1”, max. | 12.8 ms |
for technological functions | |
— parameterizable | Yes; 6 Single phase: 4 HSCs at 200 kHz; 2 HSCs at 30 kHz 4 A/B phase: 2 |
HSCs at 100 kHz; 2 HSCs at 20 kHz | |
Cable length | |
● shielded, max. | 500 m; 50m shielded for HSC inputs |
● unshielded, max. | 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 24; Relays |
Switching capacity of the outputs | |
● with resistive load, max. | 2:00 AM |
● on lamp load, max. | 30 W; 30 W with DC, 200 W with AC |
Output delay with resistive load | |
● “0” to “1”, max. | 10 ms; max. |
● “1” to “0”, max. | 10 ms; max. |
Switching frequency | |
● of the pulse outputs, with resistive load, max. | 1 Hz |
Relay outputs | |
● Number of relay outputs | 24 |
Cable length | |
● shielded, max. | 500 m |
● unshielded, max. | 150 m |
Interfaces | |
Number of industrial Ethernet interfaces | 1 |
Number of RS 485 interfaces | 1 |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes; Transformer isolated, 1,500V AC |
automatic detection of transmission rate | Yes; 10/100 Mbit/s |
Auto negotiation | Yes |
Auto crossing | Yes |
Interface types | |
● RJ 45 (Ethernet) | Yes |
Protocols | |
● PROFINET IO Controller | Yes; Since V2.4 |
● PROFINET IO Device | Yes; I-Device since V2.5 |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— Number of connectable IO Devices, max. | 8 |
— Updating time | 4 ms; The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
Address area | |
— Inputs, max. | 128 byte; Per device |
Be the first to review “6ES7 288 1SR60 0AA0 SR60 CPU” Cancel reply
Related products
-
Sale!
Delta DVP28SV11T2 PLC DVP Series
30,000.00৳Original price was: 30,000.00৳ .27,000.00৳ Current price is: 27,000.00৳ . Add to cart -
S7 200 CPU 224 DC DC DC 6ES7214 1AD23 0XB8
20,000.00৳ Add to cart -
Sale!
FX1S 30MR 001 Mitsubishi FX PLC
17,000.00৳Original price was: 17,000.00৳ .15,000.00৳ Current price is: 15,000.00৳ . Add to cart -
Sale!
Mitsubishi FX3GA 60MR CM
26,000.00৳Original price was: 26,000.00৳ .25,000.00৳ Current price is: 25,000.00৳ . Add to cart
Reviews
There are no reviews yet.