Siemens 6ES7216 2BD23 0XB0 CPU 226 AC DC Relay
25,000.00৳
Description
The Siemens 6ES7216 2BD23 0XB0 CPU 226 AC DC Relay is a programmable logic controller (PLC) from Siemens AG, a leading manufacturer of automation equipment. It is part of the SIMATIC S7-200 series, which is a compact and versatile PLC system designed for small to medium-sized automation tasks.
Here are some key features of the Siemens 6ES7216 2BD23 0XB0 CPU 226 AC DC Relay:
- CPU Type: The CPU 226 is a central processing unit (CPU) module within the SIMATIC S7-200 series. It is designed to execute control programs and manage communication with other devices in the automation system.
- Power Supply: The CPU 226 is designed to operate with an AC or DC power supply. This allows flexibility in installation and compatibility with different types of power sources commonly found in industrial environments.
- Inputs and Outputs: The CPU 226 supports a variety of digital and analog inputs and outputs (I/O). The specific configuration of I/O modules depends on the requirements of the application and can be expanded using additional modules.
- Communication Interfaces: The CPU 226 includes communication interfaces for connecting to other devices in the automation network. This can include serial communication ports (RS-232, RS-485), Ethernet ports, and fieldbus interfaces for communication with external devices such as HMI panels, drives, and sensors.
- Programming Software: The CPU 226 is programmed using Siemens’ STEP 7-Micro/WIN software, which provides a user-friendly programming environment for developing control programs. The software supports programming in ladder logic (LAD) and instruction list (IL) languages.
- Memory: The CPU 226 has built-in memory for storing the control program, user data, and system parameters. The amount of memory available depends on the specific model and configuration of the CPU.
- Reliability: Siemens PLCs are known for their robustness and reliability in industrial environments. The CPU 226 is designed to withstand harsh operating conditions such as temperature fluctuations, humidity, and electrical noise.
Overall, the Siemens 6ES7216-2BD23-0XB0 CPU 226 is a versatile and cost-effective solution for small to medium-sized automation tasks, offering a combination of performance, flexibility, and reliability for a wide range of industrial applications.
Specification of Siemens 6ES7216 2BD23 0XB0 CPU 226 AC DC Relay
Rated value (AC) | Yes Yes | |
● 120 V AC | ||
● 230 V AC | ||
Load voltage L+ | ||
● Rated value (DC) | 24 V | |
● permissible range, lower limit (DC) | 5 V | |
● permissible range, upper limit (DC) | 30 V | |
Load voltage L1 | ||
● Rated value (AC) | 100 V; 100 V AC to 230 V AC | |
● permissible range, lower limit (AC) | 5 V | |
● permissible range, upper limit (AC) | 250 V | |
● permissible frequency range, lower limit | 47 Hz | |
● permissible frequency range, upper limit | 63 Hz | |
Input current | ||
Inrush current, max. | 20 A; at 264 V | |
Encoder supply | ||
24 V encoder supply | ||
● 24 V | Yes; Permissible range: 20.4V to 28.8V Yes; electronic at 400 mA | |
● Short-circuit protection | 400 mA | |
● Output current, max. | ||
Power loss | ||
Power loss, typ. | 17 W | |
Memory | ||
Number of memory modules (optional) | 1; pluggable memory module, content identical with integral EEPROM; can additionally store recipes, data logs and other files | |
Work memory | ||
● integrated (for program) | 24 kbyte; 16 KB with active run-time edit | |
● integrated (for data) | 10 kbyte | |
Backup | ||
● present | Yes; Program: Entire program maintenance-free on integral EEPROM, programmable via CPU; data: Entire DB 1 loaded from PG/PC maintenance-free on integral EEPROM, current values of DB 1 in RAM, retentive memory bits, timers, counters, etc. maintenance-free via high-performance capacitor; optional battery for long-term buffering | |
Battery | ||
Backup battery | ||
● Backup time, max. | 100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module | |
CPU processing times | ||
for bit operations, max. | 0.22 µs | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 256 | |
Retentivity | ||
— adjustable | Yes; via high-performance capacitor or battery 1 | |
— lower limit | 256 | |
— upper limit | ||
Counting range | ||
— lower limit | 0 | |
— upper limit | 32 767 | |
S7 times | ||
● Number | 256 | |
Retentivity | ||
Time range | ||
— lower limit | 1 ms | |
— upper limit | 54 min; 4 timers: 1 ms to 30 s; 16 timers: 10 ms to 5 min; 236 | |
timers: 100 ms to 54 min | ||
Data areas and their retentivity | ||
Flag | ||
● Number, max. | 32 byte | |
● Retentivity available | Yes; M 0.0 to M 31.7 | |
● of which retentive with battery | 0 to 255, via high-performance capacitor or battery, adjustable 0 to 112 in EEPROM, adjustable | |
● of which retentive without battery | ||
Hardware configuration | ||
Number of expansion units, max. | 7; Only expansion modules of the S7-22x series can be used. Due to the limited output current, the use of expansion modules may be limited. | |
connectable programming devices/PCs | SIMATIC PG/PC, standard PC | |
Expansion modules | ||
● Analog inputs/outputs, max. | 35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) | |
148; max. 128 inputs and 120 outputs (CPU+EM) | ||
● Digital inputs/outputs, max. | 62; AS-Interface A/B slaves (CP 243-2) | |
● AS-Interface inputs/outputs, max. | ||
Digital inputs | ||
Number of digital inputs | 24 | |
Source/sink input | Yes; optionally, per group | |
Input voltage | ||
● Rated value (DC) | 24 V | |
● for signal “0” | 0 to 5 V | |
● for signal “1” | min. 15 V | |
Input current | ||
● for signal “1”, typ. | 2.5 mA | |
Input delay (for rated value of input voltage) | ||
for standard inputs | ||
— parameterizable | Yes; all | |
— at “0” to “1”, min. | 0.2 ms | |
— at “0” to “1”, max. | 12.8 ms | |
for interrupt inputs | ||
— parameterizable | Yes; I 0.0 to I 0.3 | |
for technological functions | ||
|
Yes; (E 0.0 to E 1.5) 30 kHz | |
Digital outputs | ||
Number of digital outputs | 16; Relays | |
Short-circuit protection | No; to be provided externally | |
Switching capacity of the outputs | ||
● with resistive load, max. | 2:00 AM | |
● on lamp load, max. | 200 W; 30 W with DC, 200 W with AC | |
Output voltage | ||
● for signal “1”, min. | L+/L1 | |
Output current | ||
● for signal “1” rated value | 2:00 AM | |
● for signal “0” residual current, max. | 0 mA | |
Output delay with resistive load | ||
● “0” to “1”, max. | 10 ms; all outputs | |
● “1” to “0”, max. | 10 ms; all outputs | |
Parallel switching of two outputs | ||
● for uprating | No | |
Switching frequency | ||
|
1 kHz | |
Total current of the outputs (per group) | ||
all mounting positions | ||
— up to 40 °C, max. | 10:00 AM | |
|
||
— up to 55 °C, max. | 10:00 AM | |
Relay outputs | ||
● Number of relay outputs | 16 | |
● Number of relay outputs, integrated | 16 | |
● Number of operating cycles, max. | 10 000 000; mechanically 10 million, at rated load voltage 100 000 | |
|
||
● shielded, max. | 500 m | |
● unshielded, max. | 150 m | |
Analog inputs | ||
Number of analog potentiometers | 2; Analog potentiometer; resolution 8 bit | |
Encoder | ||
Connectable encoders | ||
● 2-wire sensor | Yes 1 mA | |
— permissible quiescent current (2-wire sensor), max. | ||
1. Interface | ||
Interface type | Integrated RS 485 interface | |
Physics | RS 485 | |
Protocols | ||
● MPI | Yes; As MPI slave for data exchange with MPI masters (S7- 300/S7-400 CPUs, OPs, TDs, Push Button Panels); S7-200- internal CPU/CPU communication is possible in the MPI network with restrictions; transmission rates: 19.2/187.5 kbit/s | |
Yes; with PPI protocol for program functions, HMI functions (TD 200, OP), S7-200-internal CPU/CPU communication ; transmission rates 9.6/19.2/187.5 kbit/s | ||
Yes; As freely programmable interface with interrupt facility for serial data exchange with third-party devices with ASCII protocol transfer rates: 1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 115.2 kbps; the PC/PPI cable can also be used as RS 232/RS 485 converter | ||
● PPI | ||
● serial data exchange | ||
MPI | ||
● Transmission rate, min. | 19.2 kbit/s | |
● Transmission rate, max. | 187.5 kbit/s | |
2. Interface | ||
Interface type | Integrated RS 485 interface | |
Physics | RS 485 | |
Protocols | ||
● MPI | Yes; As MPI slave for data exchange with MPI masters (S7- 300/S7-400 CPUs, OPs, TDs, Push Button Panels); S7-200- internal CPU/CPU communication is possible in the MPI network with restrictions; transmission rates: 19.2/187.5 kbit/s | |
Yes; with PPI protocol for program functions, HMI functions (TD 200, OP), S7-200-internal CPU/CPU communication ; transmission rates 9.6/19.2/187.5 kbit/s | ||
Yes; As freely programmable interface with interrupt facility for serial data exchange with third-party devices with ASCII protocol transfer rates: 1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 115.2 kbps; the PC/PPI cable can also be used as RS 232/RS 485 converter | ||
● PPI | ||
● serial data exchange | ||
Integrated Functions | ||
Number of counters | 6; High-speed counters (30 kHz each), 32 bit (incl. sign), can be used as up/down counters or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counters)); parameterizable enable and reset input; interrupt facilities (incl. call of subroutine with any content) when the setpoint is reached; reversal in counting direction, etc. | |
Counting frequency (counter) max. | 30 kHz | |
Number of alarm inputs | 4; 4 rising edges and/or 4 falling edges | |
Potential separation | ||
Potential separation digital inputs | ||
● between the channels | Yes; Optocoupler | |
● between the channels, in groups of | 13 and 11 | |
Potential separation digital outputs | ||
● | ||
between the channels | ||
● between the channels, in groups of | ||
Permissible potential difference | ||
between different circuits | 500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC | |
Degree and class of protection | ||
Degree of protection acc. to EN 60529 | ||
● IP20 | Yes | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | 0 °C | |
● horizontal installation, max. | 55 °C | |
● vertical installation, min. | 0 °C | |
● vertical installation, max. | 45 °C | |
Air pressure acc. to IEC 60068-2-13 | ||
● permissible range, lower limit | 860 hPa | |
● permissible range, upper limit | 1 080 hPa | |
Relative humidity | ||
● Operation, min. | 5% | |
● Operation, max. | 95 %; RH class 2 in accordance with IEC 1131-2 | |
Configuration | ||
Programming | ||
● Command set | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, transmissions instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions, integer | |
maths, floating-point math instructions, numerical functions | ||
● Program processing | free cycle (OB 1), interrupt-controller, time-controlled (1 to 255 ms) | |
● Program organization | 1 OB, 1 DB, 1 SDB subroutines with/without parameter transfer | |
● Number of subroutines, max. | 64 | |
Programming language | ||
— LAD | Yes | |
— FBD | Yes Yes | |
— STL | ||
Know-how protection | ||
● User program protection/password protection | Yes; 3-stage password protection | |
Connection method | ||
Plug-in I/O terminals | Yes | |
Width | 196 mm | |
Height | 80 mm | |
Depth | 62 mm | |
Weights | ||
Weight, approx. | 660 g |
Be the first to review “Siemens 6ES7216 2BD23 0XB0 CPU 226 AC DC Relay” Cancel reply
Related products
-
Logo 6ED1052 1MD00 0BA8 Siemens PLC
18,000.00৳ Add to cart -
Sale!
PLC Mitsubishi FX1N-40MR-001
18,000.00৳Original price was: 18,000.00৳ .17,000.00৳ Current price is: 17,000.00৳ . Add to cart -
Sale!
FX1N-24MR-001 Mitsubishi FX1N PLC Series
18,000.00৳Original price was: 18,000.00৳ .16,500.00৳ Current price is: 16,500.00৳ . Add to cart -
Sale!
Mitsubishi FX3GA 60MR CM
26,000.00৳Original price was: 26,000.00৳ .25,000.00৳ Current price is: 25,000.00৳ . Add to cart
Reviews
There are no reviews yet.