6ES7314 1AG13 0AB0 Siemens S7300 PLC
Ask Price WhatsApp: +8801713-722455
Description
6ES7314 1AG13 0AB0 Siemens S7300 PLC is a Central processing unit with MPI, Integral Which power supply 24 V DC, Work memory 96 KB, must be Micro Memory Card required. If need this CPU Please contact with us, if have-not stock this 6ES7314 1AG13 0AB0 Siemens S7300 PLC then you can order this CPU, after order confirmed we can have delivered 4-5 days from china.
Specification of 6ES7314 1AG13 0AB0 Siemens S7300 PLC
| Model | 6ES7314-1AG13-0AB0 |
| Type | Simatic S7 300 CPU Module |
| General information | |
| HW functional status | 1 |
| Firmware version | V2.6 |
| Engineering with | |
| ● Programming package | STEP 7 V5.2 + SP1 or higher with HW update |
| Supply voltage | |
| Rated value (DC) | |
| ● 24 V DC | Yes |
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| external protection for power supply lines (recommendation) | 2 A min. |
| Input current | |
| Current consumption (rated value) | 0.6 A |
| Current consumption (in no-load operation), typ. | 60 mA |
| Inrush current, typ. | 2.5 A |
| I²t | 0.5 A²·s |
| Power loss | |
| Power loss, typ. | 2.5 W |
| Memory | |
| Work memory | |
| ● integrated | 96 kbyte; For program and data |
| ● expandable | No |
| Load memory | |
| ● Plug-in (MMC) | Yes |
| ● Plug-in (MMC), max. | 8 Mbyte |
| ● Data management on MMC (after last | 10 y |
| programming), min. | |
| Backup | |
| ● present | Yes; Guaranteed by MMC (maintenance-free) |
| ● without battery | Yes; Program and data |
| CPU processing times | |
| for bit operations, typ. | 0.1 µs |
| for word operations, typ. | 0.2 µs |
| for fixed point arithmetic, typ. | 2 µs |
| for floating point arithmetic, typ. | 3 µs |
| CPU-blocks | |
| Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
| DB | |
| ● Number, max. | 511; Number range: 1 to 511 |
| ● Size, max. | 16 kbyte |
| FB | |
| ● Number, max. | 1 024; Number range: 0 to 2047 |
| ● Size, max. | 16 kbyte |
| FC | |
| ● Number, max. | 1 024; Number range: 0 to 2047 |
| ● Size, max. | 16 kbyte |
| OB | |
| ● Size, max. | 16 kbyte |
| ● Number of free cycle OBs | 1; OB 1 |
| ● Number of time alarm OBs | 1; OB 10 |
| ● Number of delay alarm OBs | 1; OB 20 |
| ● Number of cyclic interrupt OBs | 1; OB 35 |
| ● Number of process alarm OBs | 1; OB 40 |
| ● Number of startup OBs | 1; OB 100 |
| ● Number of asynchronous error OBs | 4; OB 80, 82, 85, 87 |
| ● Number of synchronous error OBs | 2; OB 121, 122 |
| Nesting depth | |
| ● per priority class | 8 |
| ● additional within an error OB | 4 |
| Counters, timers and their retentivity | |
| S7 counter | |
| ● Number | 256 |
| Retentivity | |
| — adjustable | Yes |
| — lower limit | 0 |
| — upper limit | 255 |
| — preset | 8 |
| Counting range | |
| — can be set | Yes |
| — lower limit | 0 |
| — upper limit | 999 |
| IEC counter | |
| ● Number | Unlimited (limited only by RAM capacity) |
| S7 times | |
| ● Number | 256 |
| Retentivity | |
| — adjustable | Yes |
| — lower limit | 0 |
| — upper limit | 255 |
| — preset | No retentivity |
| Time range | |
| — lower limit | 10 ms |
| — upper limit | 9 990 s |
| IEC timer | |
| ● present | Yes |
| ● Type | SFB |
| ● Number | Unlimited (limited only by RAM capacity) |
| Data areas and their retentivity | |
| retentive data area in total | All, max. 64 KB |
| Flag | |
| ● Number, max. | 256 byte |
| ● Retentivity available | Yes; MB 0 to MB 255 |
| ● Retentivity preset | MB 0 to MB 15 |
| ● Number of clock memories | 8; 1 memory byte |
| Data blocks | |
| ● Retentivity adjustable | Yes; via non-retain property on DB |
| ● Retentivity preset | Yes |
| Local data | |
| ● per priority class, max. | 510 byte |
| Address area | |
| I/O address area | |
| ● Inputs | 1 kbyte |
| ● Outputs | 1 kbyte |
| Process image | |
| ● Inputs | 128 byte |
| ● Outputs | 128 byte |
| Digital channels | |
| ● Inputs | 1 024 |
| — of which central | 1 024 |
| ● Outputs | 1 024 |
| — of which central | 1 024 |
| Analog channels | |
| ● Inputs | 256 |
| — of which central | 256 |
| ● Outputs | 256 |
| — of which central | 256 |
| Hardware configuration | |
| Number of expansion units, max. | 3 |
| Number of DP masters | |
| ● integrated | 0 |
| ● via CP | 4 |
| Number of operable FMs and CPs (recommended) | |
| ● FM | 8 |
| ● CP, PtP | 8 |
| ● CP, LAN | 10 |
| Rack | |
| ● Racks, max. | 4 |
| ● Modules per rack, max. | 8 |
| Time of day | |
| Clock | |
| ● Hardware clock (real-time) | Yes |
| ● retentive and synchronizable | Yes |
| ● Backup time | 6 wk; At 40 °C ambient temperature |
| ● Deviation per day, max. | 10 s |
| Operating hours counter | |
| ● Number | 1 |
| ● Number/Number range | 0 |
| ● Range of values | 0 to 2^31 hours (when using SFC 101) |
| retentive | yes |
| Clock synchronization | |
| ● supported | Yes |
| ● to MPI, master | Yes |
| ● to MPI, slave | Yes |
| ● to DP, master | No |
| ● to DP, slave | No |
| ● in AS, master | Yes |
| ● in AS, slave | No |
| ● on Ethernet via NTP | No |
| Interfaces | |
| Number of industrial Ethernet interfaces | 0 |
| Number of PROFINET interfaces | 0 |
| Number of RS 485 interfaces | 2 |
| Number of RS 422 interfaces | 0 |
| 1. Interface | |
| Interface type | Integrated RS 485 interface |
| Physics | RS 485 |
| Isolated | No |
| Power supply to interface (15 to 30 V DC), max. | 200 mA |
| Functionality | |
| ● MPI | Yes |
| ● PROFIBUS DP master | No |
| ● PROFIBUS DP slave | No |
| ● Point-to-point connection | No |
| MPI | |
| ● Number of connections | 12 |
| ● Transmission rate, max. | 187.5 kbit/s |
| Services | |
| — PG/OP communication | Yes |
| — Routing | No |
| — Global data communication | Yes |
| S7 basic communication | Yes |
| — S7 communication | Yes |
| — S7 communication, as client | NO |
| — S7 communication, as server | Yes |
| Communication functions | |
| PG/OP communication | Yes |
| Global data communication | Yes |
| ● supported | Yes |
| ● Number of GD loops, max. | 4 |
| ● Number of GD packets, max. | 4 |
| ● Number of GD packets, transmitter, max. | 4 |
| ● Number of GD packets, receiver, max. | 4 |
| ● Size of GD packets, max. | 22 byte |
| ● Size of GD packet (of which consistent), max. | 22 byte |
| ● supported | Yes |
| ● User data per job, max. | 76 byte |
| ● User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
| S7 communication | |
| ● supported | Yes |
| ● as server | yes |
| ● as client | Yes; Via CP and loadable FB |
| ● User data per job, max. | 180 byte; With PUT/GET |
| ● User data per job (of which consistent), max. | 64 byte |
| S5 compatible communication | |
| ● supported | Yes; via CP and loadable FC |
| Number of connections | |
| ● overall | 12 |
| ● usable for PG communication | 11 |
| — reserved for PG communication | 1 |
| — adjustable for PG communication, min. | 1 |
| — adjustable for PG communication, max. | 11 |
| ● usable for OP communication | 11 |
| — reserved for OP communication | 1 |
| — adjustable for OP communication, min. | 1 |
| — adjustable for OP communication, max. | 11 |
| ● usable for S7 basic communication | 8 |
| — reserved for S7 basic communication | 0 |
| — adjustable for S7 basic communication, min. | 0 |
| adjustable for S7 basic communication, max. | 88 |
| S7 message functions | |
| Number of login stations for message functions, max. | 12; Depending on the configured connections for PG/OP and S7 basic communication |
| Process diagnostic messages | Yes |
| simultaneously active Alarm-S blocks, max. | 40 |
| Test commissioning functions | |
| Status block | Yes |
| Single step | Yes |
| Number of breakpoints | 2 |
| Status/control | |
| ● Status/control variable | Yes |
| ● Variables | Inputs, outputs, memory bits, DB, times, counters 30 |
| ● Number of variables, max. | |
| — of which status variables, max. | 30 |
| — of which control variables, max. | 14 |
| Forcing | |
| ● Forcing | Yes |
| ● Forcing, variables | Inputs, outputs |
| ● Number of variables, max. | 10 |
| Diagnostic buffer | |
| ● present | Yes 100 |
| ● Number of entries, max. | No |
| — adjustable | |
| Configuration | |
| Configuration software | |
| ● STEP 7 | Yes; V5.2 SP1 or higher with HW update |
| Programming | |
| ● Command set | see instruction list |
| ● Nesting levels | 8 |
| ● System functions (SFC) | see instruction list |
| ● System function blocks (SFB) | see instruction list |
| Programming language | |
| — LAD | Yes |
| — FBD | Yes |
| — STL | Yes |
| — SCL | Yes |
| — CFC | Yes |
| — GRAPH | Yes |
| — HiGraph® | Yes |
| Yes | |
| Know-how protection | |
| ● User program protection/password protection | Yes |
| Dimensions | |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 130 mm |
| Weights | |
| Weight, approx. | 280 g |
Be the first to review “6ES7314 1AG13 0AB0 Siemens S7300 PLC” Cancel reply
Related products
-
Sale!

Delta PLC DVP28SV11R2 Delta DVP PLC
30,000.00৳Original price was: 30,000.00৳ .27,000.00৳ Current price is: 27,000.00৳ . Add to cart -
Sale!

Delta DVP14SS211R PLC DVP Series
12,000.00৳Original price was: 12,000.00৳ .9,500.00৳ Current price is: 9,500.00৳ . Add to cart -
Sale!

Mitsubishi FX3GA 40MR CM
24,000.00৳Original price was: 24,000.00৳ .23,500.00৳ Current price is: 23,500.00৳ . Add to cart -
Sale!

PLC Mitsubishi FX1N-40MR-001
18,000.00৳Original price was: 18,000.00৳ .17,000.00৳ Current price is: 17,000.00৳ . Add to cart
Reviews
There are no reviews yet.