6ES7211 1BE40 0XB0 1211C AC DC RLY
Ask Price WhatsApp: +8801713-722455
Description
The 6ES7211 1BE40 0XB0 1211C AC DC RLY is the Programmable Logic Controller (PLC) of SIMATIC S7-1200 series CPU, this part number is the CPU 1211C and compact CPU AC/DC/relay, also has onboard I/O: 6 Digital Input (DI) 24 V DC; 4 Digital Output (DO) relay 2 A; 2 Analog Input (AI) 0-10 V DC, power supply: AC 85-264 V AC at 47-63 Hz & program/data memory 75 KB. If need 6ES7211 1BE40 0XB0 CPU 1211C AC DC RLY then you can contact us BAT Power Solution via WhatsApp: +8801713722455.
Specification of 6ES7211 1BE40 0XB0 1211C AC DC RLY
Part number | 6ES7211-1BE40-0XB0 |
General information | |
Product type designation | CPU 1211C AC/DC/relay |
Firmware version | V4.6 |
Engineering with | |
● Programming package | STEP 7 V18 or higher |
Supply voltage | |
Rated value (AC) | |
● 120 V AC | Yes |
● 230 V AC | Yes |
permissible range, lower limit (AC) | 85 V |
permissible range, upper limit (AC) | 264 V |
Line frequency | |
● permissible range, lower limit | 47 Hz |
● permissible range, upper limit | 63 Hz |
Input current | |
Current consumption (rated value) | 60 mA at 120 V AC; 30 mA at 240 V AC |
Current consumption, max. | 180 mA at 120 V AC; 90 mA at 240 V AC |
Inrush current, max. | 20 A; at 264 V |
I²t | 0.8 A²·s |
Output current | |
for backplane bus (5 V DC), max. | 750 mA; Max. 5 V DC for CM |
Encoder supply | |
24 V encoder supply | |
● 24 V | 20.4 to 28.8V |
Power loss | |
Power loss, typ. | 10 W |
Memory | |
Work memory | |
● integrated | 75 kbyte |
Load memory | |
● integrated | 1 Mbyte |
● Plug-in (SIMATIC Memory Card), max. | with SIMATIC memory card |
Backup | |
● present | Yes |
● maintenance-free | Yes |
● without battery | Yes |
Digital inputs | |
Number of digital inputs | 6; Integrated |
● of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 40 °C, max. | 6 |
Input voltage | |
● Rated value (DC) | 24 V |
● for signal “0” | 5 V DC at 1 mA |
● for signal “1” | 15 V DC at 2.5 mA |
Input current | |
● for signal “1”, typ. | 4 mA; nominal |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in |
groups of four | |
— at “0” to “1”, min. | 0.2 ms |
— at “0” to “1”, max. | 12.8 ms |
for interrupt inputs | |
— parameterizable | Yes |
for technological functions | |
— parameterizable | Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz |
Cable length | |
● shielded, max. | 500 m; 50 m for technological functions |
● unshielded, max. | 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 4; Relays |
Switching capacity of the outputs | |
● with resistive load, max. | 2:00 AM |
● on lamp load, max. | 30 W with DC, 200 W with AC |
Output delay with resistive load | |
● “0” to “1”, max. | 10 ms; max. |
● “1” to “0”, max. | 10 ms; max. |
Relay outputs | |
● Number of relay outputs | 4 |
● Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 |
Cable length | |
● shielded, max. | 500 m |
● unshielded, max. | 150 m |
Analog inputs | |
Number of analog inputs | 2 |
Input ranges | |
● Voltage | Yes |
Input ranges (rated values), voltages | |
● 0 to +10 V | Yes |
— Input resistance (0 to 10 V) | ≥100k ohms |
Cable length | |
● shielded, max. | 100 m; twisted and shielded |
Analog outputs | |
Number of analog outputs | 0 |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 10 bit |
● Integration time, parameterizable | Yes |
● Conversion time (per channel) | 625 µs |
Encoder | |
Connectable encoders | |
● 2-wire sensor | Yes |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types | |
● RJ 45 (Ethernet) | Yes |
● Number of ports | 1 |
● integrated switch | No |
Protocols | |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | Yes |
● SIMATIC communication | Yes |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | No |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
— Isochronous mode | No |
— IRT | No |
— PROFIenergy | No |
— Prioritized startup | Yes |
— Number of IO devices with prioritized startup, max. | 16 |
— Number of connectable IO Devices, max. | 16 |
— Number of connectable IO Devices for RT, max. | 16 |
— of which in line, max. | 16 |
— Activation/deactivation of IO Devices | Yes |
— Number of IO Devices that can be simultaneously | 8 |
activated/deactivated, max. | |
— Updating time | The minimum value of the update time also depends on the communication |
component set for PROFINET IO, on the number of IO devices and the quantity | |
of configured user data. | |
PROFINET IO Device | |
Services | |
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
— Isochronous mode | No |
— IRT | No |
— PROFIenergy | Yes |
— Shared device | |
— Number of IO Controllers with shared device, max. | 2 |
Protocols | |
Supports protocol for PROFINET IO | Yes |
PROFIsafe | No |
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
OPC UA | Yes; OPC UA Server |
AS-Interface | Yes; CM 1243-2 required |
Protocols (Ethernet) | |
● TCP/IP | Yes |
● DHCP | No |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
Redundancy mode | |
Media redundancy | |
— MRP | No |
— MRPD | No |
SIMATIC communication | |
● S7 routing | Yes |
Open IE communication | |
● TCP/IP | Yes |
— Data length, max. | 8 kbyte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 8 kbyte |
● UDP | Yes |
— Data length, max. | 1 472 byte |
Web server | |
● supported | Yes |
● User-defined websites | Yes |
OPC UA | |
● Runtime license required | Yes; “Basic” license required |
● OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required |
— Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, |
Basic256Sha256 | |
— User authentication | “anonymous” or by user name & password |
— Number of sessions, max. | 10 |
— Number of subscriptions per session, max. | 5 |
— Sampling interval, min. | 100 ms |
— Publishing interval, min. | 200 ms |
— Number of server methods, max. | 20 |
— Number of monitored items, recommended max. | 1 000 |
— Number of server interfaces, max. | 2 |
— Number of nodes for user-defined server interfaces, | 2 000 |
max. | |
Further protocols | |
● MODBUS | Yes |
communication functions / header | |
S7 communication | |
● supported | Yes |
● as server | Yes |
● as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Number of connections | |
● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved |
/ 10 max; Total Connections: 34 reserved / 64 max | |
Free fall | |
● Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation | |
● min. | -20 °C |
● max. | 60 °C |
● horizontal installation, min. | -20 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | -20 °C |
● vertical installation, max. | 50 °C |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
● Operation, min. | 795 hPa |
● Operation, max. | 1 080 hPa |
● Storage/transport, min. | 660 hPa |
● Storage/transport, max. | 1 080 hPa |
Altitude during operation relating to sea level | |
● Installation altitude, min. | -1 000 m |
● Installation altitude, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Relative humidity | |
● Operation, max. | 95 %; no condensation |
Vibrations | |
● Vibration resistance during operation acc. to IEC 60068- 2-6 | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail |
● Operation, tested according to IEC 60068-2-6 | Yes |
Shock testing | |
● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Pollutant concentrations | |
● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD | Yes |
— FBD | |
— SCL | |
Know-how protection | |
● User program protection/password protection | Yes |
● Copy protection | |
● Block protection | |
Access protection | |
● protection of confidential configuration data | Yes |
● Protection level: Write protection | |
● Protection level: Read/write protection | |
● Protection level: Complete protection | |
programming / cycle time monitoring / header | |
● adjustable | Yes |
Dimensions | |
Width | 90 mm |
Height | 100 mm |
Depth | 75 mm |
Weights | |
Weight, approx. | 420 g |
Be the first to review “6ES7211 1BE40 0XB0 1211C AC DC RLY” Cancel reply
Related products
-
Sale!
Delta PLC DVP32ES200T Delta DVP Series PLC
21,000.00৳Original price was: 21,000.00৳ .20,500.00৳ Current price is: 20,500.00৳ . Add to cart -
Simatic S7 200 CPU 224 6ES7214-1BD23-0XB8
20,000.00৳ Add to cart -
Sale!
Mitsubishi FX3GA 60MR CM
26,000.00৳Original price was: 26,000.00৳ .25,000.00৳ Current price is: 25,000.00৳ . Add to cart -
Sale!
Delta DVP28SV11T2 PLC DVP Series
30,000.00৳Original price was: 30,000.00৳ .27,000.00৳ Current price is: 27,000.00৳ . Add to cart
Reviews
There are no reviews yet.