6ES7 288 1SR30 0AA0 Siemens S7 200 smart SR30 CPU
Ask Price WhatsApp: +8801713-722455
Category: PLC
Tags: 6es7 288 1sr30 0aa0, 6es7288 1sr30 0aa0, S7 200 smart plc price, Siemens S7 200 smart, SR30 CPU
Description
6ES7 288 1SR30 0AA0 Siemens S7 200 smart SR30 CPU is the Programmable logic controller of SIMATIC S7-200 SMART, The CPU SR30 is the standard CPU & has many advanced functions AC/DC/relay, onboard I/O: 18 DI 24 V DC; 12 DO relay 2 A; power supply: AC 85-264 V AC at 47-63 Hz, program/data memory 30 KB.
Specification of 6ES7 288 1SR30 0AA0 Siemens S7 200 smart SR30 CPU
General information | |
Product type designation | CPU SR30 AC/DC/Relay |
Engineering with | |
STEP 7 Micro/WIN SMART | |
Installation type/mounting | |
Rail mounting | Yes; Standard – DIN rail |
Supply voltage | |
Rated value (AC) | |
● 120 V AC | Yes |
● 230 V AC | Yes |
permissible range, lower limit (AC) | 85 V |
permissible range, upper limit (AC) | 264 V |
Reverse polarity protection | Yes |
Line frequency | |
● permissible range, lower limit | 47 Hz |
● permissible range, upper limit | 63 Hz |
Input current | |
Current consumption (rated value) | 72 mA; at 240 V AC |
Current consumption, max. | 136 mA; At 120 V AC |
Inrush current, max. | 8.9 A; at 264 V |
Output current | |
Current output, max. | 300 mA; 24 V DC Sensor Power |
for backplane bus (5 V DC), max. | 1.4 A; max. 5 V DC for EM bus |
Power loss | |
Power loss, max. | 14 W; max. |
Memory | |
Type of memory | DDR |
Flash | Yes Yes |
RAM | 12 kbyte |
Memory available for user data | 18 kbyte; Program memory |
Memory size | Yes; microSDHC Card (optional) |
Micro Memory Card | |
Backup | |
● present | Yes; Maintenance free, RTC requires 7 days. |
CPU processing times | |
for bit operations, typ. | 150 ns; / instruction |
for word operations, typ. | 1.2 µs; / instruction |
for floating point arithmetic, typ. | 3.6 µs; / instruction |
Address area | |
I/O address area | |
● Inputs | 144 byte; 256 bit of digital inputs & 56 words of analog inputs |
● Outputs | 144 byte; 256 bit of digital outputs & 56 words of analog outputs |
Time of day | |
Clock | |
● Type | Hardware clock, no battery backup Yes |
● Hardware clock (real-time) | 7 d |
● Backup time | 120 s; within 120s/month at 25 °C |
● Deviation per day, max. | |
Digital inputs | |
Number of digital inputs | 18 |
● of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 40 °C, max. | 18 |
Input voltage | |
● Type of input voltage | DC |
● Rated value (DC) | 24 V |
● for signal “0” | 5 V DC at 1 mA |
● for signal “1” | 15 V DC at 2.5 mA |
Input current | |
● for signal “0”, max. (permissible quiescent current) | 1 mA |
● for signal “1”, typ. | 4 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in |
groups of four | |
— at “0” to “1”, min. | 0.2 ms |
— at “0” to “1”, max. | 12.8 ms |
for interrupt inputs | |
— parameterizable | Yes |
for technological functions | |
— parameterizable | Yes; 6 Single phase: 5 HSCs at 200 kHz; 1 HSCs at 30 kHz 4 A/B phase: 3 |
HSCs at 100 kHz; 1 HSC at 20 kHz | |
Cable length | |
● shielded, max. | 500 m; 50m shielded for HSC inputs |
● unshielded, max. | 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 12; Relays |
Switching capacity of the outputs | |
● with resistive load, max. | 2:00 AM |
● on lamp load, max. | 30 W; 30 W with DC, 200 W with AC |
Output delay with resistive load | |
● “0” to “1”, max. | 10 ms; max. |
● “1” to “0”, max. | 10 ms; max. |
Switching frequency | |
● of the pulse outputs, with resistive load, max. | 1 Hz |
Relay outputs | |
● Number of relay outputs | 12 |
Cable length | |
● shielded, max. | 500 m |
● unshielded, max. | 150 m |
Interfaces | |
Number of industrial Ethernet interfaces | 1 |
Number of RS 485 interfaces | 1 |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes; Transformer isolated, 1,500V AC |
automatic detection of transmission rate | Yes; 10/100 Mbit/s |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types | |
● RJ 45 (Ethernet) | Yes |
Protocols | |
● PROFINET IO Controller | Yes; Since V2.4 |
● PROFINET IO Device | Yes; I-Device since V2.5 |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— Number of connectable IO Devices, max. | 8 |
— Updating time | 4 ms; The minimum value of the update time also depends on the |
communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. | |
Address area | |
— Inputs, max. | 128 byte; Per device |
— Outputs, max. | 128 byte; Per device |
2. Interface | |
Interface type | RS 485 (max. 187.5 kbps) |
Interface types | |
● RS 485 | Yes |
PROFIBUS DP master | |
Services | |
— S7 communication | Yes |
Protocols | |
Supports protocol for PROFINET IO | Yes; RT Controller (since FW V2.4) & I-Device (since FW V2.5) |
PROFIBUS | Yes; Via CM DP module |
Protocols (Ethernet) | |
● TCP/IP | Yes |
communication functions / header | |
S7 communication | |
● supported | Yes |
● as server | Yes |
● as client | Yes |
Test commissioning functions | |
Forcing | |
● Forcing | Yes |
Integrated Functions | |
PID controller | Yes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops |
Number of pulse outputs | 3 |
EMC | |
Interference immunity against discharge of static electricity | |
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
— Test voltage at air discharge | |
— Test voltage at contact discharge | 8 kV |
4 kV | |
Interference immunity against high-frequency electromagnetic fields | |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 | Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, |
50% ED (to IEC 61000-4-3) | |
Interference immunity to cable-borne interference | |
● Interference immunity on supply lines acc. to IEC 61000- 4-4 | Yes; 2 kV acc. to IEC 61000-4-4, burst |
● Interference immunity on signal cables acc. to IEC 61000- 4-4 | |
Yes; ±2 kV acc. to IEC 61000-4-4, Burst | |
Interference immunity against conducted variable disturbance induced by high-frequency fields | |
● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 | Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
Emission of radio interference acc. to EN 55 011 | |
● Limit class A, for use in industrial areas | Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Emission of conducted and non-conducted interference | |
● Interference emission via line/AC current cables | EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
CE mark | Yes |
Ambient conditions | |
Free fall | |
● Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation | |
● min. | 0 °C |
● max. | 55 °C |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 55 °C |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 45 °C |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
● Storage/transport, min. | 660 hPa |
● Storage/transport, max. | 1 080 hPa |
Altitude during operation relating to sea level | |
● Installation altitude, min. | -1 000 m |
● Installation altitude, max. | 2 000 m |
Relative humidity | |
● Operation at 25 ℃ without condensation, max. | 95% |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
Dimensions | |
Width | 110 mm |
Height | 100 mm |
Depth | 81 mm |
Weights | |
Weight, approx. | 435 g |
Be the first to review “6ES7 288 1SR30 0AA0 Siemens S7 200 smart SR30 CPU” Cancel reply
Related products
-
Sale!
Delta DVP14SS211R PLC DVP Series
12,000.00৳Original price was: 12,000.00৳ .9,500.00৳ Current price is: 9,500.00৳ . Add to cart -
Sale!
Mitsubishi FX3GA 60MR CM
26,000.00৳Original price was: 26,000.00৳ .25,000.00৳ Current price is: 25,000.00৳ . Add to cart -
Sale!
Siemens 6ED1 052-1FB00-0BA6 Siemens Logo Controller
18,000.00৳Original price was: 18,000.00৳ .17,500.00৳ Current price is: 17,500.00৳ . Add to cart -
Sale!
PLC Mitsubishi FX1N-40MR-001
18,000.00৳Original price was: 18,000.00৳ .17,000.00৳ Current price is: 17,000.00৳ . Add to cart
Reviews
There are no reviews yet.